熱鍍鋅電纜橋架的安裝要注意什么?
熱鍍鋅電纜橋架便是使用電解設備把電纜橋架通過(guò)除油栓洗之后,放入成分為鋅鹽的溶液里邊,而且銜接電解設備的負級。在電纜橋架對面放置鋅板,銜接在電解設備的整潔,然后接通電源。是使用電源正級向負級定向移動(dòng),就會(huì )在電纜橋架上面沉積一層鋅冷鍍電纜橋架是先加工后鍍鋅,首要便是起到防腐的作用。他和重防腐涂料是相同的冷鍍鋅電纜橋架的出產(chǎn)和涂裝工程,也是涉及到了環(huán)境維護和施工人員以及公共工作衛生,環(huán)境維護也是冷鍍鋅電纜橋架的一個(gè)首要發(fā)展方向。冷凍間電纜橋架具有十分好的功能,便是體現在下面這幾個(gè)方面。不含有PH.cr。Hg等等這些重金屬。
Hot dip galvanized cable tray is a process of using electrolytic equipment to wash the cable tray through a degreasing plug, then placing it in a solution containing zinc salts, and connecting it to the negative stage of the electrolytic equipment. Place a zinc plate opposite the cable tray, connect it neatly to the electrolysis equipment, and then connect the power supply. When using the power supply to move from positive to negative, a layer of zinc cold plating will be deposited on the cable tray. The cable tray is processed first and then galvanized, with the primary purpose being to prevent corrosion. He is the same as the heavy-duty anti-corrosion coating in the production and coating engineering of cold galvanized cable trays, which also involves environmental maintenance, construction personnel, and public work hygiene. Environmental maintenance is also a primary development direction of cold galvanized cable trays. The cable tray in the freezer room has excellent environmental protection functions, which are reflected in the following aspects. Does not contain PH.cr. Hg and other heavy metals.
而且它還歸屬于厚膜型資料,觸電功能還好。在通過(guò)了充分的攪拌以后,少加或者是不必加稀釋劑就能夠涂裝施工。因為冷鍍鋅固體分含量高達百分之77,一次無(wú)氣噴涂能夠獲得比較高的膜厚,減少了有機溶劑的發(fā)揮量,下降枯燥能耗,這些都是有利于環(huán)境維護的措施。而且鍍鋅電纜橋架是大型電力工程,不能夠缺少的一種建筑設施資料,因為鍍鋅電纜橋架,它的特別加工工藝和構成資料比較于其他的電纜具有更多的優(yōu)勢和特性,這也讓鍍鋅電纜橋架的使用范圍變得愈加的廣泛了。
And it also belongs to thick film materials, with good electric shock function. After sufficient mixing, coating construction can be carried out with little or no diluent added. Because the solid content of cold galvanizing is as high as 77%, a single airless spraying can achieve a relatively high film thickness, reduce the amount of organic solvents used, and reduce dry energy consumption. These are measures that are beneficial for environmental maintenance. Moreover, galvanized cable trays are a type of building facility information that cannot be lacking in large-scale power engineering, because their special processing technology and composition information have more advantages and characteristics compared to other cables, which also makes the scope of use of galvanized cable trays more extensive.
因這兩種金屬在橋架上的結合是十分細密的,所以鍍鋅電纜條件有很強的結實(shí)功能,而且它的耐磨性也是的。
Because the combination of these two metals on the bridge is very fine, galvanized cables have strong durability and wear resistance.
兩組電纜橋架在同一高度平行敷設時(shí),其間凈距不小于0.6m。槽式大跨距由室外進(jìn)入建筑物內時(shí),橋架向外的斜度不得小于1/100。內纜線(xiàn)筆直敷設時(shí),在纜線(xiàn)的上端和每距離1.5米處應固定在橋架的支架上,水平敷設時(shí), 在纜線(xiàn)的首、尾、轉彎及每距離3~5米處進(jìn)行固定。
When two sets of cable trays are laid parallel at the same height, the clear distance between them shall not be less than 0.6m. When the trough type large-span enters the building from outside, the slope of the bridge to the outside shall not be less than 1/100. When laying the inner cable straight, it should be fixed on the support of the bridge at the upper end of the cable and every 1.5 meters away. When laying horizontally, it should be fixed at the beginning, end, turn, and every 3-5 meters away.
電纜引下點(diǎn)方位及引下方法,一般來(lái)說(shuō),大批電纜引下可用筆直彎接板和筆直引上架,少數電纜引下可用導板或引管,注明引下方法即可。電纜橋架宜高出地上2.2米以上,橋架頂部距頂棚或其它障礙物不應小于0.3米,橋架寬度不宜小于0.1米,橋架內橫斷面的填充率不應逾越50。
The direction and method of cable lead down points. Generally speaking, for a large number of cables, straight bending plates and straight lead up racks can be used, while for a few cables, guide plates or pipes can be used, indicating the lead down method. The cable tray should be raised 2.2 meters above the ground, and the distance from the top of the tray to the ceiling or other obstacles should not be less than 0.3 meters. The width of the tray should not be less than 0.1 meters, and the filling rate of the cross-section inside the tray should not exceed 50.
橋架與用電設備交越時(shí),其間的凈距不小于0.5m。 在平行圖上繪出橋架的路由,要注明橋架起點(diǎn)、完畢、拐彎點(diǎn)、分支點(diǎn)及升降點(diǎn)的坐標或定位尺度、標高,如能制作橋架敷設軸側圖,則對材料核算將更準。 直線(xiàn)段:注明全長(cháng)、橋架層數、標高、類(lèi)型及標準。
When crossing the bridge and electrical equipment, the clear distance between them shall not be less than 0.5m. Draw the route of the cable tray on a parallel diagram, indicating the coordinates or positioning scale and elevation of the starting point, end, turning point, branch point, and lifting point of the cable tray. If a cable tray laying axis side diagram can be made, the material accounting will be more accurate. Straight section: indicate the total length, number of bridge layers, elevation, type, and standard.