電纜橋架的接地線(xiàn)如何保護?
電纜橋架的接地線(xiàn)是直接接地的導線(xiàn),也可以稱(chēng)為回路。當危險發(fā)生時(shí),它被認為是一條生命線(xiàn),通過(guò)將高壓直接輸送到地面。因此,保護橋架式電纜橋架的地線(xiàn)非常重要。
The grounding wire of the cable tray is a directly grounded conductor, which can also be called a circuit. When a hazard occurs, it is considered a lifeline by delivering high pressure directly to the ground. Therefore, it is very important to protect the ground wire of cable tray.
絕緣不良或潮濕環(huán)境會(huì )導致托盤(pán)式電纜橋架設備外殼產(chǎn)生一定量的靜電,嚴重時(shí)會(huì )發(fā)生觸電事故。為防止發(fā)生意外,可以將電線(xiàn)接到橋架式走線(xiàn)槽的金屬表面,并將電線(xiàn)的另一端接地。如果電纜漏電,地線(xiàn)會(huì )將電源接地并釋放。
Poor insulation or humid environment will lead to a certain amount of static electricity in the shell of tray type cable tray equipment, and electric shock accidents will occur in serious cases. In order to prevent accidents, the wire can be connected to the metal surface of the bridge type trunking and the other end of the wire can be grounded. If the cable leaks electricity, the ground wire will ground the power supply and release it.
如何保護山東電纜橋架系統中的接地線(xiàn)?
How to protect the grounding wire in Shandong cable tray system?
當意外電壓施加到斷開(kāi)的設備和線(xiàn)路時(shí),它是保護和認證操作員的重要工具。根據頒布的相關(guān)規定,電纜橋架的接地線(xiàn)需要采用直徑為4mm以上的裸銅軟線(xiàn)。
When unexpected voltage is applied to disconnected equipment and lines, it is an important tool for protecting and certifying operators. According to the relevant regulations issued, the grounding wire of cable tray needs to use bare copper flexible wire with a diameter of more than 4mm.
使用過(guò)去的托盤(pán)式電纜橋架系統構建接地干線(xiàn)電路時(shí),需要滿(mǎn)足以下要求:
When the tray type cable grounding system is used, the following requirements shall be met:
1、線(xiàn)槽橋架式電纜橋架、橋架橋架式電纜橋架、階梯橋架式電纜橋架的端接頭接觸電阻不應大于0.00033。接地孔不得有絕緣涂層。
1. The contact resistance of end joints of trunking type cable tray, bridge type cable tray and ladder type cable tray shall not be greater than 0.00033. The grounding hole shall not have insulating coating.
2、膨脹節或連續鉸鏈用編織銅線(xiàn)。截面積應根據工程實(shí)際接地系統和現行相關(guān)標準確定。
2. Braided copper wire for expansion joint or continuous hinge. The cross-sectional area shall be determined according to the actual grounding system of the project and the current relevant national standards.
3、沿橋架式橋架全長(cháng)敷設地線(xiàn)時(shí),橋架式橋架和梯形橋架的所有段(包括非直段)應該牢固地與地線(xiàn)連接.接地線(xiàn)
3. When laying the ground wire along the full length of the bridge type bridge, all sections (including non straight sections) of the bridge type bridge and trapezoidal bridge shall be firmly connected with the ground wire ground wire
4、接地部分的連接螺栓需要有墊圈。
4. The connecting bolts of the grounding part shall be provided with washers.