配電箱安裝的14個(gè)禁忌:
配電箱是現代家庭和企業(yè)中必不可少的電力分配設備,它的安裝和使用對于電力系統的和穩定性關(guān)重要。然而,在配電箱的安裝和使用過(guò)程中,由于意識不足或者不了解相關(guān)規定,可能會(huì )導致電氣事故的發(fā)生。因此,在安裝和使用配電箱時(shí),需要遵守一些禁忌,以確保和可靠性。
Distribution boxes are essential power distribution equipment in modern homes and businesses, and their installation and use are crucial for the safety and stability of the power system. However, during the installation and use of the distribution box, due to insufficient safety awareness or ignorance of relevant regulations, Electrical safety accidents may occur. Therefore, when installing and using distribution boxes, it is necessary to follow some taboos to ensure safety and reliability.
下面山東電纜橋架廠(chǎng)家來(lái)講講配電箱安裝14個(gè)禁忌:
Next, the manufacturer of cable tray in Shandong will talk about 14 taboos for the installation of distribution box:
1、配電箱內應裝設專(zhuān)用的漏電保護開(kāi)關(guān)。
1. A dedicated leakage protection switch should be installed inside the distribution box.
2、在進(jìn)入總配電箱的電纜入口處,應裝置額定電流不低于10a的漏電保護開(kāi)關(guān)。
2. At the cable inlet of the main distribution box, a leakage protection switch with a rated current of not less than 10a should be installed.
3、同一回路控制相和主變壓器負荷側的總漏電保護開(kāi)關(guān)不應裝在一處。
3. The total leakage protection switch on the control phase and load side of the main transformer in the same circuit should not be installed together.
4、配電箱內的照明和動(dòng)力電纜宜集中敷設,不宜穿管敷設;動(dòng)力電纜宜沿管道敷設,照明電纜可采用金屬管(或帶屏蔽層的軟管)埋地敷設。
4. The lighting and power cables inside the distribution box should be laid in a centralized manner and should not be laid through pipes; Power cables should be laid along pipelines, while lighting cables can be buried in metal pipes (or hoses with shielding layers).
5、配電箱內不宜安裝過(guò)多的儀表,以免增加接線(xiàn)點(diǎn),造成線(xiàn)路紊亂。
5. It is not advisable to install too many instruments in the distribution box to avoid adding wiring points and causing circuit disorder.
6、總配電箱內一般不宜裝設超過(guò)三個(gè)計量表。
6. It is generally not advisable to install more than three measuring meters in the main distribution box.
7、配電箱內所有電器設備的安裝均應有固定基礎。
7. All electrical equipment in the distribution box should be installed with a fixed foundation.
8、總配電箱及分段配電箱內的所有電線(xiàn)電纜應選用銅芯截面不小于6mm2的多股軟導線(xiàn);嚴禁使用鋁絞線(xiàn)。
8. All wires and cables in the main distribution box and segmented distribution box should be multi stranded flexible conductors with a copper core cross-section of not less than 6mm2; The use of aluminum stranded wires is strictly prohibited.
9、總配電箱各分配電箱的電源進(jìn)線(xiàn),采用三條電纜從總配電箱經(jīng)分段開(kāi)關(guān)連接。
9. The power incoming lines from the main distribution box to each distribution box are connected by three cables through segmented switches from the main distribution box.
10、每臺用電設備都有專(zhuān)用的供電開(kāi)關(guān)。
10. Each electrical device has a dedicated power supply switch.
11、總配電箱內應設置專(zhuān)用的接地保護和重復接地裝置。
11. Special grounding protection and repeated grounding devices should be installed inside the main distribution box.
12、總配電箱應有可靠的防雨措施,嚴禁滲水漏電。
12. The main distribution box should have reliable rainproof measures, and water leakage and leakage are strictly prohibited.
13、禁止私自改裝配電箱和拆卸配電箱的保護裝置。
13. It is prohibited to modify the distribution box and dismantle the protective device of the distribution box without permission.
14、禁止在配電箱周?chē)逊盼kU品和危險物品。
14. It is prohibited to stack dangerous goods and materials around the distribution box.
以上14個(gè)禁忌是在配電箱安裝和使用過(guò)程中需要嚴格遵守的。在安裝和使用配電箱時(shí),要多多關(guān)注其中的事項,更多事項就來(lái)我們網(wǎng)站http://yxsdz.cn咨詢(xún)!
The above 14 taboos need to be strictly followed during the installation and use of distribution boxes. When installing and using distribution boxes, it is important to pay more attention to the issues involved. For more information, please visit our website http://yxsdz.cn consulting service